Product image of Iasocholine (Fluorocholine (18f) Chloride) supplied by GNH India

Iasocholine

Active Ingredient:
Fluorocholine (18f) Chloride
Origin:
EU

Iasocholine (Fluorocholine (18f) Chloride)

Fluorocholine (18F) Chloride, the active ingredient in Iasocholine, is a radiopharmaceutical presented as a sterile solution for injection for intravenous use. It is employed to visualize tissues with increased phospholipid synthesis, primarily in patients undergoing PET imaging for prostate cancer and other malignancies that exhibit high choline metabolism.

GNH India supplies Iasocholine as a licensed, GDP‑compliant international pharmaceutical supplier serving hospitals, oncology centres, diagnostic imaging facilities and research institutions worldwide, with adherence to EU quality standards. The product complies with European Union regulatory requirements for radiopharmaceuticals.

Manufacturer / TM Owner

Curium Austria Gmbh

1
Pack/s
This product is added to your enquiry list

Request a Quote

Please fill out the form below and our team will get back to you shortly with pricing and further information.

A minimum order value applies. Our team will confirm the exact amount or quantity after reviewing your requirements.

Indications & Clinical Uses

Iasocholine is used in PET imaging to assess cancers that demonstrate elevated choline metabolism.

  • Prostate cancer: enables PET imaging to detect, localize and stage disease, improving treatment planning.
  • High‑grade glioma: facilitates visualization of proliferating tumor tissue for diagnostic and therapeutic monitoring.
  • Other malignant lesions with high choline uptake: assists in locating and characterizing tumors such as head‑and‑neck or lung cancers where choline metabolism is increased.

How It Works

  • Fluorocholine (18F) chloride is a choline analogue that enters cells via choline transporters and is phosphorylated by choline kinase. The phosphorylated compound is incorporated into phosphatidylcholine, a major membrane phospholipid, leading to accumulation in cells with up‑regulated phospholipid synthesis such as proliferating tumor cells. The 18F radionuclide emits positrons, which are detected by PET scanners to generate high‑resolution images of metabolic activity.

Side Effects

Adverse reactions to Iasocholine are generally related to the injection procedure and the radiopharmaceutical nature of the product.

Common Side Effects

  • Injection site discomfort: mild pain or irritation at the site of administration.
  • Nausea: transient feeling of sickness after injection.
  • Flushing: brief warmth or redness of the skin.
  • Headache: mild to moderate headache occurring shortly after dosing.
  • Dizziness: temporary light‑headedness.
  • Fatigue: short‑term tiredness post‑administration.

Serious or Rare Side Effects

  • Anaphylactic reaction: severe allergic response requiring immediate medical attention.
  • Severe hypotension: marked drop in blood pressure that may cause fainting.
  • Cardiac arrhythmia: irregular heart rhythm potentially life‑threatening.
  • Radiation‑induced skin injury: localized tissue damage at high exposure sites.

Precautions & Warnings

Specific safety considerations should be observed when using Iasocholine.

  • Pregnancy: unknown risk; avoid unless diagnostic benefit outweighs potential harm.
  • Breastfeeding: unknown; consider discontinuing nursing during and after administration.
  • Renal impairment: assess renal function; altered clearance may affect tracer distribution.
  • Hepatic impairment: use with caution; monitor for possible accumulation.
  • Known hypersensitivity: contraindicated in patients with allergy to fluorocholine or any formulation component.
  • Store at 2–8 °C: keep refrigerated, protect from light, do not freeze or shake.

Avoid Interactions

Potential drug interactions may influence tracer uptake or patient safety.

Major Interactions (Avoid)

  • Concurrent administration of other PET tracers: may cause competitive uptake and interfere with image interpretation.
  • High‑dose corticosteroids: can suppress choline kinase activity, reducing tracer accumulation.
  • Certain chemotherapeutic agents: may alter membrane synthesis, diminishing tracer uptake.

Moderate Interactions (Monitor Closely)

  • Beta‑blockers: may affect cardiovascular response to injection.
  • Diuretics: can modify renal excretion of the tracer.
  • Iodinated contrast agents: may affect PET quantification if performed shortly before or after tracer injection.

Frequently Asked Questions

Iasocholine contains fluorocholine (18F) chloride, a PET tracer used to image prostate cancer and other malignancies with high choline metabolism, helping clinicians locate, stage, and monitor disease.

Fluorocholine is a choline analogue that enters cells via choline transporters, is phosphorylated by choline kinase, and incorporated into phosphatidylcholine. The 18F isotope emits positrons, producing PET images that reflect cellular proliferation.

The administered activity is determined by the prescribing nuclear medicine physician or radiologist based on patient weight, scanner sensitivity, and regulatory guidelines. The dose is prepared in a radiopharmacy and administered intravenously under controlled conditions.

Safety data are limited; the product has an unknown pregnancy category. Because it involves ionizing radiation, it is generally avoided in pregnant or nursing patients unless the diagnostic benefit outweighs the risk and appropriate precautions are taken.

Submit an enquiry on the product page at gnhindia.com, specifying the required quantity. GNH India works with hospitals, pharmacies and procurement teams worldwide, verifies trade or institutional credentials, and then provides pricing, availability, shipping details (including cold‑chain logistics) and necessary import documentation.

Compared with 18F‑FDG, fluorocholine targets choline metabolism rather than glucose, offering higher specificity for prostate cancer and certain other tumors. It may provide clearer delineation of lesions with low FDG uptake but shares similar logistical requirements for radiopharmacy preparation and handling.

Iasocholine must be stored refrigerated at 2–8 °C in its original shielded container, protected from light. It should not be frozen or shaken. Prior to use, the solution is drawn under aseptic conditions and administered promptly to maintain radiochemical purity.

The product is supplied as a sterile solution for injection and is administered intravenously, typically as a bolus injection followed by a short waiting period (usually 10–20 minutes) before PET imaging begins, allowing tissue uptake of the tracer.

Serious adverse events include hypersensitivity reactions such as anaphylaxis, severe hypotension, arrhythmias, and radiation‑related tissue injury. Immediate medical attention is required if signs of allergic reaction, cardiovascular instability, or unexpected radiation exposure occur.

Patients with known hypersensitivity to fluorocholine or any component of the formulation should avoid use. It is also contraindicated in pregnant or nursing women unless essential, and caution is advised in individuals with severe renal or hepatic impairment where tracer clearance may be altered.

Published by

GNH India Pharmaceuticals Limited

Licensed pharmaceutical supplier

Last updated:

Disclaimer

At GNH India, we aim to provide information that is expert-reviewed, accurate, and reliable. However, all content on this platform is intended for general informational purposes only and does not constitute professional medical advice, diagnosis, or treatment. While efforts are made to maintain accuracy and currency, the information may contain errors, omissions, or may not reflect the latest developments. Always consult a qualified healthcare professional regarding any medical concerns.

All product names, brand names, trademarks and registered trademarks displayed on this website are the property of their respective owners. This website and its operator are not affiliated with, endorsed by, or authorized by any such trade mark owners unless expressly stated. Any reference to product names or trademarks is made solely for descriptive and informational purposes. No commercial relationship, sponsorship, approval, or association with any trademark owner should be inferred. Information provided herein does not constitute promotion, advertising, or an offer for sale of any medicinal product and is intended solely for general informational purposes.

All trademarks and brand names displayed on this website are used strictly in accordance with the provisions of the Trade Marks Act, 1999, specifically Sections 30 and 30(1) governing fair use. Trademark ownership has been accurately attributed under the "Manufacturer/ TM Owner" section in compliance with statutory requirements.

Ordering Process

Simple, Secure, and Seamless

Learn how our streamlined ordering process guarantees fast, compliant, and reliable access to essential medicines worldwide.

Quote request form

01

Submit Quote Request Form

Tell us what medications you need by filling out our simple form and uploading a valid document.

Price estimate review

02

We Review & Send Estimate

Our licensed pharmacists will verify your details and provide you with a detailed cost estimate.

Secure payment

03

Confirm & Make Payment

Discuss any queries, approve the estimate, and complete your payment.

Worldwide delivery

04

Get Delivered

Your medicines, safely packed and delivered to your door or nearest airport — hassle-free.

Quality You Can Trust

Our internationally recognized certifications underscore our commitment to safety, quality, and excellence.