Product image of Indium (In-111) Chloride Curium (Indium (111in)) supplied by GNH India

Indium (In-111) Chloride Curium

Active Ingredient:
Indium (111in)
Origin:
EU

Indium (In-111) Chloride Curium (Indium (111in))

Indium-111, the active ingredient in Indium (In-111) Chloride Curium, is a radiopharmaceutical presented as an injectable solution for intravenous use. It is employed for scintigraphic imaging of infection, inflammation, tumors and bone marrow in adult patients.

GNH India supplies Indium (In-111) Chloride Curium as a licensed, GDP‑compliant international pharmaceutical supplier serving hospitals, transplant centres, oncology centres, pharmacies and clinics worldwide. The company emphasizes quality assurance, regulatory compliance and reliable cold‑chain logistics for radiopharmaceutical distribution across multiple continents and emerging markets.

Manufacturer / TM Owner

Curium Netherlands B.V.

1
Pack/s
This product is added to your enquiry list

Request a Quote

Please fill out the form below and our team will get back to you shortly with pricing and further information.

A minimum order value applies. Our team will confirm the exact amount or quantity after reviewing your requirements.

Indications & Clinical Uses

  • Indium-111 chloride is used in diagnostic imaging to visualize specific disease processes.
  • Infection and inflammation imaging: provides scintigraphic visualization of infectious or inflammatory sites.
  • Leukocyte labeling for abscess detection: labels patient white blood cells to locate abscesses and focal infections.
  • Tumor imaging: highlights malignant lesions to assist in cancer staging and treatment planning.
  • Bone marrow imaging: delineates marrow activity for assessment of hematologic disorders.

How It Works

  • Indium-111 chloride is a gamma‑emitting radionuclide that, when bound to antibodies, peptides or autologous leukocytes, emits photons detectable by a gamma camera. After intravenous injection, the labeled compound circulates and accumulates in target tissues based on biological affinity, allowing high‑resolution scintigraphic images of infection, inflammation, tumor or marrow activity. The short physical half‑life of approximately 2.8 days limits radiation exposure while providing sufficient imaging time.

Side Effects

Adverse reactions to Indium-111 chloride are generally related to the injection procedure and radiation exposure.

Common Side Effects

  • Injection site pain: mild discomfort at the venipuncture site.
  • Transient flushing: brief feeling of warmth or redness.
  • Nausea: mild upset stomach occurring shortly after administration.
  • Headache: temporary headache not requiring treatment.

Serious or Rare Side Effects

  • Anaphylaxis: severe allergic reaction with airway compromise.
  • Radiation‑induced tissue injury: localized damage to organs receiving high dose.
  • Hematologic toxicity: significant reduction in blood cell counts.

Precautions & Warnings

When handling Indium-111 chloride, observe the following precautions.

  • Radiation safety: follow institutional protocols to limit exposure to staff and patients.
  • Pregnancy: avoid use unless benefits outweigh potential fetal radiation risk.
  • Breastfeeding: discontinue breastfeeding for an appropriate period after administration.
  • Renal function: assess kidney function as excretion is primarily renal.
  • Allergic history: screen for prior hypersensitivity to radiopharmaceuticals.
  • Store at 2-8°C: keep refrigerated, protect from light, do not freeze or shake.

Avoid Interactions

Potential drug interactions with Indium-111 chloride should be considered.

Major Interactions (Avoid)

  • Concurrent radiopharmaceuticals: may result in cumulative radiation dose.
  • High‑dose chemotherapy: can increase bone marrow toxicity when combined.
  • Immunosuppressive agents: may alter leukocyte labeling efficiency.

Moderate Interactions (Monitor Closely)

  • Iodinated contrast agents: can affect image quality and biodistribution.
  • Beta‑blockers: may influence hemodynamic response to injection.
  • Steroids: may modify inflammatory uptake patterns.

Frequently Asked Questions

Indium-111 chloride is a radiopharmaceutical used primarily for diagnostic scintigraphic imaging. It helps visualize sites of infection, inflammation, malignant tumors and bone marrow activity, providing clinicians with detailed functional information that complements anatomical imaging techniques.

Indium-111 emits gamma photons that can be detected by a gamma camera. When attached to antibodies, peptides or a patient’s own white blood cells, the radionuclide travels to specific tissues based on biological affinity, allowing the emitted photons to create high‑resolution images of the targeted area.

The administered activity of Indium-111 chloride is determined by the prescribing physician or nuclear medicine specialist. Dosing is individualized according to the specific diagnostic indication, the labeling method used and the patient’s body weight or surface area, and follows local regulatory guidelines.

Data on the safety of Indium-111 chloride in pregnant or lactating women are limited. Because the agent delivers ionising radiation, it is generally avoided unless the diagnostic benefit clearly outweighs the potential risk to the fetus or infant. Consultation with a radiology and obstetrics specialist is essential.

To request Indium-111 chloride, submit an enquiry on the product page at gnhindia.com specifying the required quantity. GNH India works with hospitals, pharmacies and procurement teams worldwide, verifies trade or institutional credentials, and then provides pricing, availability, shipping details (including cold‑chain logistics) and any necessary import documentation.

Compared with commonly used Technetium‑99m agents, Indium-111 offers a longer half‑life (≈2.8 days) and higher energy gamma emissions, which can be advantageous for delayed imaging and cell labeling. However, its higher radiation dose and need for specialized gamma cameras may limit use to specific clinical scenarios where its unique properties are required.

Indium-111 chloride must be stored refrigerated at 2‑8 °C, protected from light, and never frozen or shaken. The product should be handled in a shielded environment by trained personnel, and all waste must be managed according to local radiation safety regulations.

The radiopharmaceutical is supplied as an injectable solution and is administered intravenously by a qualified nuclear medicine professional. Depending on the clinical protocol, it may be given directly or used to label cells or compounds that are then re‑injected for imaging.

The most serious risks include severe allergic reactions such as anaphylaxis, radiation‑induced tissue injury at high‑dose sites, and hematologic toxicity leading to significant reductions in blood cell counts. Prompt recognition and appropriate medical management are essential if any of these events occur.

Patients with a known hypersensitivity to Indium‑111 or any component of the formulation should avoid the product. It is also contraindicated in pregnant women unless absolutely necessary, in individuals with severe renal impairment without dose adjustment, and in patients who have recently received other high‑dose radiopharmaceuticals.

Published by

GNH India Pharmaceuticals Limited

Licensed pharmaceutical supplier

Last updated:

Disclaimer

At GNH India, we aim to provide information that is expert-reviewed, accurate, and reliable. However, all content on this platform is intended for general informational purposes only and does not constitute professional medical advice, diagnosis, or treatment. While efforts are made to maintain accuracy and currency, the information may contain errors, omissions, or may not reflect the latest developments. Always consult a qualified healthcare professional regarding any medical concerns.

All product names, brand names, trademarks and registered trademarks displayed on this website are the property of their respective owners. This website and its operator are not affiliated with, endorsed by, or authorized by any such trade mark owners unless expressly stated. Any reference to product names or trademarks is made solely for descriptive and informational purposes. No commercial relationship, sponsorship, approval, or association with any trademark owner should be inferred. Information provided herein does not constitute promotion, advertising, or an offer for sale of any medicinal product and is intended solely for general informational purposes.

All trademarks and brand names displayed on this website are used strictly in accordance with the provisions of the Trade Marks Act, 1999, specifically Sections 30 and 30(1) governing fair use. Trademark ownership has been accurately attributed under the "Manufacturer/ TM Owner" section in compliance with statutory requirements.

Ordering Process

Simple, Secure, and Seamless

Learn how our streamlined ordering process guarantees fast, compliant, and reliable access to essential medicines worldwide.

Quote request form

01

Submit Quote Request Form

Tell us what medications you need by filling out our simple form and uploading a valid document.

Price estimate review

02

We Review & Send Estimate

Our licensed pharmacists will verify your details and provide you with a detailed cost estimate.

Secure payment

03

Confirm & Make Payment

Discuss any queries, approve the estimate, and complete your payment.

Worldwide delivery

04

Get Delivered

Your medicines, safely packed and delivered to your door or nearest airport — hassle-free.

Quality You Can Trust

Our internationally recognized certifications underscore our commitment to safety, quality, and excellence.