Technetium Tc-99m - V4 (Ultra-Technekow)

Trade Name : Ultra-Technekow

Curium US LLC

INJECTION, SOLUTION

Strength 1.5 Ci/1

TECHNETIUM TC-99M SODIUM PERTECHNETATE

Delivery Process

Submit a Request

You can fill in a request for your medicine through the form provided. You can access the form by clicking on the ‘Get Price’ button.

We’ll Get in Touch

Once we review your request, we’ll send you an estimated price for the medicine within 2-5 days.

Confirmation and Payment

You can fill in a request for your medicine through the form provided. You can access the form by clicking on the ‘Get Price’ button.

Submit a Request

You can fill in a request for your medicine through the form provided. You can access the form by clicking on the ‘Get Price’ button.

Product information is meant for

Wholesalers Suppliers Exporters Doctors MOH Tender Supplies Hospitals Brand CROs Comparator Supplies Generic Cooperate Sourcing Individual Patients Indian Institutional Buyers

Disclaimer

Trade Marks displayed in compliance with provisions of: Trademark Act, 1999 u/s 30 and 30 (1) of "Fair use"

GNH India is WHO GDP and ISO 9001 2015 Certified Pharmaceutical Wholesaler/ Supplier/ Exporters/ Importer from India of Technetium Tc-99m - V4 (Ultra-Technekow) which is also known as Ultra-Technekow and Manufactured by Curium US LLC. It is available in strength of 1.5 Ci/1 per ml. Read more

Technetium Tc-99m - V4 (Ultra-Technekow) is supplied for Tenders/ Emergency imports/ Un - licensed, Specials, Orphan drug/ Name patient line/ RLD supplies/ Reference listed drugs/ Comparator Drug/ Bio-Similar/ Innovator samples For Clinical trials.  Click to know price.     Read less

Packaging and Delivery

Validated Cold Chain Shipment

We deliver your medicines through a validated cold chain shipment process. This process is used as these medicines need to manufactured, transported and stored at very specific temperatures, utilizing thermal and refrigerated packaging methods.

Inquire directly from our website and get 5% off on any medicine!

We deliver your medicines through a validated cold chain shipment process. This process is used as these medicines need to manufactured, transported and stored at very specific temperatures, utilizing thermal and refrigerated packaging methods.

Read more

About GNH

We deliver your medicines through a validated cold chain shipment process. This process is used as these medicines need to manufactured, transported and stored at very specific temperatures, utilizing thermal and refrigerated packaging methods.

We deliver your medicines through a validated cold chain shipment process. This process is used as these medicines need to manufactured, transported and stored at very specific temperatures, utilizing thermal and refrigerated packaging methods.

Read more
  • No data
  • The Ultra-Technekow V4 Generator is prepared with fission-produced molybdenum Mo-99 adsorbed onto alumina in a column shielded by lead, tungsten, or depleted uranium. The column assembly and shielding are encased in a plastic container that is covered with a plastic elution hood.u00a0 The elution hood has an opening for the column assembly double inlet needles and an opening for the single outlet needle.u00a0 The needles accommodate the sterile eluant vials and sterile evacuated collection vials.u00a0 A sterile vial containing a bacteriostat is supplied with the generator for the customer to aseptically seal the outlet needle after each elution. u00a0u00a0
  • This terminally sterilized generator provides a closed system for the production of sterile metastable technetium Tc-99m, which is produced by the decay of molybdenum Mo-99. Incorporated between the column outlet and the collection vial is a sterile 0.22 micrometer filter. Sterile, non-pyrogenic isotonic solutions of Sodium Pertechnetate Tc 99m can be obtained conveniently by periodic aseptic elution of the generator. These solutions should be clear, colorless, and free from any particulate matter.u00a0 The Sodium Pertechnetate Tc 99m Injection is suitable for intravenous injection and direct instillation.
  • The carrier-free solution may be used as is, or diluted to the proper concentration. Over the life of the generator, an elution will contain an amount of technetium Tc-99m in direct proportion to the quantity of Mo-99 decay since the previous elution of the generator. The quantity of Tc-99m in the eluate is determined by quantity of Mo-99 on the column, and the elapsed time between elutions.
  • Each eluate of the generator should not contain more than the USP limit of 0.15 kilobecquerel molybdenum Mo-99 per megabecquerel technetium Tc-99m (0.15 microcurie Mo-99 per millicurie Tc-99m) per administered dose at the time of administration and an aluminum ion concentration of not more than 10 micrograms per milliliter of the generator eluate, both of which must be determined by the user before administration.
  • Since the eluate does not contain an antimicrobial agent, it should not be used after 12 hours from the time of generator elution.
  • The pertechnetate ion distributes in the body similarly to the iodide ion but is not organified when trapped in the thyroid gland. Pertechnetate concentrates in the thyroid gland, salivary glands, stomach and choroid plexus. After intravenous administration it gradually equilibrates with the extracellular space. A fraction is promptly excreted via the kidneys.
  • Following the administration of Sodium Pertechnetate Tc 99m as an eye drop, the drug mixes with tears within the conjunctival space. Within seconds to minutes it leaves the conjunctival space and escapes into the inferior meatus of the nose through the nasolacrimal drainage system. During this process the pertechnetate ion passes through the canaliculi, the lacrimal sac and the nasolacrimal duct. In the event of any anatomical or functional blockage of the drainage system there will be a backflow resulting in tearing (epiphora). Thus the pertechnetate escapes the conjunctival space in the tears.
  • While the major part of the pertechnetate escapes within a few minutes of normal drainage and tearing, it has been documented that there is some degree of transconjunctival absorption with turnover of 1.5% per minute in normal individuals, 2.1% per minute in patients without any sac and 2.7% per minute in patients with inflamed conjunctiva due to chronic dacryocystitis. Individual values may vary but these rates are probably representative and indicate that the maximum possible pertechnetate absorbed will remain below one thousandth of that used in other routine diagnostic procedures.
  • The Ultra-Technekowu2122 V4 generator is a source of sodium pertechnetate Tc 99m for use in the preparation of FDA-approved diagnostic radiopharmaceuticals, as described in the labeling of these diagnostic radiopharmaceutical kits.
  • Sodium Pertechnetate Tc 99m is used as an agent for:
  • u00a0u00a0u00a0u00a0Thyroid Imaging u00a0u00a0u00a0u00a0Salivary Gland Imaging u00a0u00a0u00a0u00a0Urinary Bladder Imaging (direct isotopic cystography) for detection of vesico-ureteral reflux u00a0u00a0u00a0u00a0Nasolacrimal Drainage System Imaging (dacryoscintigraphy)
  • Sodium Pertechnetate Tc 99m is used as an agent for:
  • u00a0u00a0u00a0u00a0Thyroid Imaging u00a0u00a0u00a0u00a0Urinary Bladder Imaging (direct isotopic cystography) for the detection of vesico-ureteral reflux
  • None.
  • Radiation risks associated with the use of Sodium Pertechnetate Tc 99m are greater in pediatric patients than in adults and, in general, the younger the patient the greater the risk owing to greater absorbed radiation doses and longer life expectancy. These greater risks should be taken firmly into account in all benefit risk assessments involving pediatric patients.
  • Long-term cumulative radiation exposure may be associated with an increased risk of cancer.
  • Only use generator eluant specified for use with the Ultra-Technekow V4 Generator.u00a0 Do not use any other generator eluant or saline from any other source.
  • Radiopharmaceuticals should be used only by physicians who are qualified by training and experience in the safe use and handling of radionuclides and whose experience and training have been approved by the appropriate government agency authorized to license the use of radionuclides. u00a0
  • As in the use of any radioactive material, care should be taken to minimize radiation exposure to the patient consistent with proper patient management and to ensure minimum radiation exposure to occupational workers.
  • After the termination of the nasolacrimal imaging procedure, blowing the nose and washing the eyes with sterile distilled water or an isotonic sodium chloride solution will further minimize the radiation dose.
  • Since the eluate does not contain an antimicrobial agent, it should not be used after 12 hours from time of generator elution.
  • Allergic reactions including anaphylaxis have been reported infrequently following the administration of Sodium Pertechnetate Tc 99m.
  • Sodium Pertechnetate Tc 99m is administered by intravenous injection. u00a0When imaging the nasolacrimal drainage system, instill the Sodium Pertechnetate Tc 99m by the use of a device such as a micropipette or similar method which will ensure the accuracy of the dose.
  • For imaging the urinary bladder and ureters (direct isotopic cystography), the Sodium Pertechnetate Tc 99m is administered by direct instillation aseptically into the bladder via a urethral catheter, following which the catheter is flushed with approximately 200 mL of sterile saline directly into the bladder.
  • The suggested dose ranges employed for various diagnostic indications in the average ADULT PATIENT (70 kg) are as follows:
  • Vesico-ureteral imaging:u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 u00a0u00a0u00a0u00a0u00a0 18.5 to 37 MBq (0.5 to 1 mCi)Thyroid gland imaging:u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 u00a0u00a0u00a0u00a0u00a0 37 to 370 MBq (1 to 10 mCi)Salivary gland imaging:u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 u00a0u00a0u00a0u00a0u00a0 37 to 185 MBq (1 to 5 mCi)Nasolacrimal drainage system: u00a0u00a0u00a0 u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 Maximum dose of 3.7 MBq (100 u00b5Ci)
  • The recommended dosages in PEDIATRIC PATIENTS are:
  • Vesico-ureteral imaging:u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 u00a0u00a0u00a0u00a0u00a0 18.5 to 37 MBq (0.5 to 1 mCi)Thyroid gland imaging:u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 u00a0u00a0u00a0u00a0u00a0 2.22 to 2.96 MBq (60 to 80 u00b5Ci) per kg body weight
  • The patient dose should be measured by a suitable radioactivity calibration system immediately prior to administration.
  • Parenteral drug products should be inspected visually for particulate matter and discoloration prior to administration whenever solution and container permit. u00a0If the solution is discolored, discontinue use of the generator immediately. The solution to be administered as the patient dose should be clear, colorless, and contain no particulate matter.
  • The estimated absorbed radiation doses to an average and patient from an intravenous injection of various doses of Sodium Pertechnetate Tc 99m distributed uniformly in the total body are shown in Tables 5 and 6. u00a0
  • Table 5. Absorbed Radiation Doses from Intravenous Injection
  • To obtain radiation absorbed dose in rads (30 mCi dose) from the above table, divide individual organ values by a factor of 10 (does not apply for effective dose).
  • Table 6. Pediatric Absorbed Radiation Doses (mGy) from Intravenous Injection
  • To obtain radiation absorbed dose in rads (30 mCi dose) from the above table, divide individual organ values by a factor of 10 (does not apply for effective dose).
  • The estimated absorbed radiation doses to an ADULT patient from the nasolacrimal imaging procedure using a maximum dose of 3.7 megabecquerels (100 microcuries) of Sodium Pertechnetate Tc 99m are shown in Table 7.
  • Table 7. Absorbed Radiation Doses from Dacryoscintigraphy
  • *Assuming no blockage of draining system.
  • In pediatric patients, an average 30 minute exposure to 37 MBq (1 mCi) of Tc-99m pertechnetate following instillation for direct cystography, will result in the following estimated radiation doses:
  • Table 8. Absorbed Radiation Doses from Cystography (PEDIATRIC)
  • The Ultra-Technekow V4 (Technetium Tc 99m) Generators contain the following amount of molybdenum Mo-99 at the date and time of calibration stated on the label.
  • Catalog No.
  • 9010u00a0u00a0 u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 37 gigabecquerelsu00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 (1.0 curie) NDC 69945-010-03
  • 9015u00a0u00a0 u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 55.5 gigabecquerelsu00a0u00a0u00a0u00a0u00a0u00a0 u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 (1.5 curies) NDC 69945-015-04
  • 9020u00a0u00a0 u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 74 gigabecquerelsu00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 (2.0 curies) NDC 69945-020-05
  • 9025u00a0u00a0 u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 92.5 gigabecquerelsu00a0u00a0u00a0u00a0u00a0u00a0 u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 (2.5 curies)NDC 69945-025-06
  • 9030u00a0u00a0 u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 111 gigabecquerelsu00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 (3.0 curies)NDC 69945-030-07
  • 9035u00a0u00a0 u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 129.5 gigabecquerelsu00a0u00a0u00a0u00a0u00a0u00a0 u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 (3.5 curies)NDC 69945-035-08
  • 9051u00a0u00a0 u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 185 gigabecquerelsu00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 (5.0 curies)NDC 69945-051-09
  • 9060u00a0u00a0 u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 222 gigabecquerelsu00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 (6.0 curies)NDC 69945-060-10
  • 9075u00a0u00a0 u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 277.5 gigabecquerelsu00a0u00a0u00a0u00a0u00a0u00a0 u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 (7.5 curies)NDC 69945-075-11
  • 9110u00a0u00a0 u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 407 gigabecquerelsu00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 (11.0 curies)NDC 69945-110-12
  • 9140u00a0u00a0 u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 518 gigabecquerelsu00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 (14.0 curies)NDC 69945-140-13
  • 9160u00a0u00a0 u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 592 gigabecquerelsu00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 (16.0 curies)NDC 69945-160-14
  • 9190u00a0u00a0 u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 703 gigabecquerelsu00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0u00a0 (19.0 curies)NDC 69945-190-15
  • Each generator is supplied with the following components for the elution of the generator:
  • u00a0u00a0u00a0u00a01 - Technestat Vial, 5 mL, containing 0.5 mL of 1.5 mg/mL methylparaben and 0.2 mg/mL propylparaben, sterile, non-pyrogenic
  • u00a0u00a0u00a0u00a01 - Package Insert
  • SUPPLIED SEPARATELY
  • 30 - Evacuated Collecting Vials, 30 mL, sterile, non-pyrogenic, supplied with:
  • u00a0u00a0u00a0u00a090 - Radioactive Materials Labels u2013 Collection Vial (30 en, 30 fr, 30 es)
  • u00a0u00a0u00a0u00a090 - Radioactive Materials Labels u2013 Elution Shield u00a0(30 en, 30 fr, 30 es)
  • u00a0u00a0u00a0u00a01 - Package Insert
  • 30 - Generator Eluant, 0.9% sodium chloride, sterile, non-pyrogenic, available in 5,u00a0
  • u00a0u00a0u00a0u00a010 mL, or 20 mL volumes, with 1 package insert. The eluant does not contain an antimicrobial agent.
  • Storage
  • Store generator and Sodium Pertechnetate Tc 99m solution at controlled room temperature 20-25u00b0C (68-77u00b0F) [see USP Controlled Room Temperature].
  • Expiration Date
  • The generator should not be used after the expiration date stated on the label.
  • The expiration time of the Sodium Pertechnetate Tc 99m solution is not later than 12 hours after time of elution. u00a0If the eluate is used to reconstitute a kit, the radiolabeled kit should not be used after 12 hours from the time of generator elution or after the expiration time stated on the labeling for the prepared drug, whichever is earlier.
  • NOTE 1: u00a0u00a0u00a0u00a0Immediately upon delivery, the generator should be placed within a minimum of one-inch of lead shielding in such a manner u00a0u00a0u00a0u00a0 u00a0u00a0u00a0u00a0 u00a0u00a0u00a0u00a0 u00a0u00a0u00a0u00a0so as to minimize radiation exposure to attending personnel.
  • NOTE 2: u00a0u00a0u00a0u00a0Wear waterproof gloves during the elution procedure and during subsequent reconstitution of kits with the eluate.
  • NOTE 3: u00a0u00a0u00a0u00a0Use a shielded syringe to withdraw patient dose or to transfer Sodium Pertechnetate Tc 99m into mixing vials during kit u00a0u00a0u00a0u00a0 u00a0u00a0u00a0u00a0 u00a0u00a0u00a0u00a0 u00a0u00a0u00a0u00a0reconstitution.
  • NOTE 4: u00a0u00a0u00a0u00a0The needles in the generator are sterile beneath their covers, and the generator has been cleaned underneath the top cover. u00a0u00a0u00a0u00a0 u00a0u00a0u00a0u00a0 u00a0u00a0u00a0u00a0 u00a0u00a0u00a0u00a0Additional disinfection of these areas with agents containing alcohol may unfavorably influence the Tc-99m yield.
  • Eluting the generator every 24 hours will provide optimal amounts of Sodium Pertechnetate Tc 99m. However, the generator may be eluted whenever sufficient amounts of technetium Tc-99m have accumulated within the column.
  • For Example
  • Elution
  • Subsequent Elutions
  • Vacuum Loss
  • If the vacuum in the collecting vial is lost, do not attempt to re-evacuate the vial, but discard and use a new collecting vial.
  • Expired Generator Disposal
  • This generator may be received, used and administered only by authorized persons in designated clinical settings. Its receipt, storage, use, transfer and disposal are subject to the regulations and/or appropriate licenses of local competent official organizations.
  • Curium and the Curium logo are trademarks of a Curium company.u00a92018 Curium US LLC. All Rights Reserved.
  • Manufactured by:Curium US LLCMaryland Heights, MO 63043 USAMade in USA
  • R12/2018
  • STERILE
  • 9010-9190
  • CURIUMu2122
  • Ultra-Technekow V4(TECHNETIUM Tc 99m GENERATOR)n n
  • WARNING
  • Rx only
  • See package insert for directions for use.
  • Tc-99m Half Life = 6 hr
  • CAUTIONn- RADIOACTIVE MATERIAL
  • Patent/Brevet/Patente:n n
  • Manufactured by/Fabrique par/Fabricado por:Curium USu00a0LLCMaryland Heights, MO 63043Made in USA/Fabrique aux Etats-Unis/Hecho en E.U.A.
  • Distributed in Canada by/Distribue au Canda par:Curium Canada Inc.Laval, QC, Canada, H7T-2R3DIN: 02441608
  • CURIUM n
  • A901C0R03/2019
  • Arrayn- Array
  • Ultra-Technekow V4(TECHNETIUM Tc 99m GENERATOR)n n
  • WARNING
  • Rx only
  • See package insert for directions for use.
  • Tc-99m Half Life = 6 hr
  • CAUTIONn- RADIOACTIVE MATERIAL
  • Patent/Brevet/Patente:n n
  • Manufactured by/Fabrique par/Fabricado por:Curium USu00a0LLCMaryland Heights, MO 63043Made in USA/Fabrique aux Etats-Unis/Hecho en E.U.A.
  • Distributed in Canada by/Distribue au Canda par:Curium Canada Inc.Laval, QC, Canada, H7T-2R3DIN: 02441608
  • CURIUM n
  • A901C0R03/2019
  • Ultra-Technekow V4(TECHNETIUM Tc 99m GENERATOR)n n
  • WARNING
  • Rx only
  • See package insert for directions for use.
  • Tc-99m Half Life = 6 hr
  • CAUTIONn- RADIOACTIVE MATERIAL
  • Patent/Brevet/Patente:n n
  • Manufactured by/Fabrique par/Fabricado por:Curium USu00a0LLCMaryland Heights, MO 63043Made in USA/Fabrique aux Etats-Unis/Hecho en E.U.A.
  • Distributed in Canada by/Distribue au Canda par:Curium Canada Inc.Laval, QC, Canada, H7T-2R3DIN: 02441608
  • CURIUM n
  • A901C0R03/2019
  • Ultra-Technekow V4(TECHNETIUM Tc 99m GENERATOR)n n
  • WARNING
  • Rx only
  • See package insert for directions for use.
  • Tc-99m Half Life = 6 hr
  • CAUTIONn- RADIOACTIVE MATERIAL
  • Patent/Brevet/Patente:n n
  • Manufactured by/Fabrique par/Fabricado por:Curium USu00a0LLCMaryland Heights, MO 63043Made in USA/Fabrique aux Etats-Unis/Hecho en E.U.A.
  • Distributed in Canada by/Distribue au Canda par:Curium Canada Inc.Laval, QC, Canada, H7T-2R3DIN: 02441608
  • CURIUM n
  • A901C0R03/2019
  • Ultra-Technekow V4(TECHNETIUM Tc 99m GENERATOR)n n
  • WARNING
  • Rx only
  • See package insert for directions for use.
  • Tc-99m Half Life = 6 hr
  • CAUTIONn- RADIOACTIVE MATERIAL
  • Patent/Brevet/Patente:n n
  • Manufactured by/Fabrique par/Fabricado por:Curium USu00a0LLCMaryland Heights, MO 63043Made in USA/Fabrique aux Etats-Unis/Hecho en E.U.A.
  • Distributed in Canada by/Distribue au Canda par:Curium Canada Inc.Laval, QC, Canada, H7T-2R3DIN: 02441608
  • CURIUM n
  • A901C0R03/2019
  • Ultra-Technekow V4(TECHNETIUM Tc 99m GENERATOR)n n
  • WARNING
  • Rx only
  • See package insert for directions for use.
  • Tc-99m Half Life = 6 hr
  • CAUTIONn- RADIOACTIVE MATERIAL
  • Patent/Brevet/Patente:n n
  • Manufactured by/Fabrique par/Fabricado por:Curium USu00a0LLCMaryland Heights, MO 63043Made in USA/Fabrique aux Etats-Unis/Hecho en E.U.A.
  • Distributed in Canada by/Distribue au Canda par:Curium Canada Inc.Laval, QC, Canada, H7T-2R3DIN: 02441608
  • CURIUM n
  • A901C0R03/2019
  • Ultra-Technekow V4(TECHNETIUM Tc 99m GENERATOR)n n
  • WARNING
  • Rx only
  • See package insert for directions for use.
  • Tc-99m Half Life = 6 hr
  • CAUTIONn- RADIOACTIVE MATERIAL
  • Patent/Brevet/Patente:n n
  • Manufactured by/Fabrique par/Fabricado por:Curium USu00a0LLCMaryland Heights, MO 63043Made in USA/Fabrique aux Etats-Unis/Hecho en E.U.A.
  • Distributed in Canada by/Distribue au Canda par:Curium Canada Inc.Laval, QC, Canada, H7T-2R3DIN: 02441608
  • CURIUM n
  • A901C0R03/2019
  • Ultra-Technekow V4(TECHNETIUM Tc 99m GENERATOR)n n
  • WARNING
  • Rx only
  • See package insert for directions for use.
  • Tc-99m Half Life = 6 hr
  • CAUTIONn- RADIOACTIVE MATERIAL
  • Patent/Brevet/Patente:n n
  • Manufactured by/Fabrique par/Fabricado por:Curium USu00a0LLCMaryland Heights, MO 63043Made in USA/Fabrique aux Etats-Unis/Hecho en E.U.A.
  • Distributed in Canada by/Distribue au Canda par:Curium Canada Inc.Laval, QC, Canada, H7T-2R3DIN: 02441608
  • CURIUM n
  • A901C0R03/2019
  • Ultra-Technekow V4(TECHNETIUM Tc 99m GENERATOR)n n
  • WARNING
  • Rx only
  • See package insert for directions for use.
  • Tc-99m Half Life = 6 hr
  • CAUTIONn- RADIOACTIVE MATERIAL
  • Patent/Brevet/Patente:n n
  • Manufactured by/Fabrique par/Fabricado por:Curium USu00a0LLCMaryland Heights, MO 63043Made in USA/Fabrique aux Etats-Unis/Hecho en E.U.A.
  • Distributed in Canada by/Distribue au Canda par:Curium Canada Inc.Laval, QC, Canada, H7T-2R3DIN: 02441608
  • CURIUM n
  • A901C0R03/2019
  • Ultra-Technekow V4(TECHNETIUM Tc 99m GENERATOR)n n
  • WARNING
  • Rx only
  • See package insert for directions for use.
  • Tc-99m Half Life = 6 hr
  • CAUTIONn- RADIOACTIVE MATERIAL
  • Patent/Brevet/Patente:n n
  • Manufactured by/Fabrique par/Fabricado por:Curium USu00a0LLCMaryland Heights, MO 63043Made in USA/Fabrique aux Etats-Unis/Hecho en E.U.A.
  • Distributed in Canada by/Distribue au Canda par:Curium Canada Inc.Laval, QC, Canada, H7T-2R3DIN: 02441608
  • CURIUM n
  • A901C0R03/2019
  • Ultra-Technekow V4(TECHNETIUM Tc 99m GENERATOR)n n
  • WARNING
  • Rx only
  • See package insert for directions for use.
  • Tc-99m Half Life = 6 hr
  • CAUTIONn- RADIOACTIVE MATERIAL
  • Patent/Brevet/Patente:n n
  • Manufactured by/Fabrique par/Fabricado por:Curium USu00a0LLCMaryland Heights, MO 63043Made in USA/Fabrique aux Etats-Unis/Hecho en E.U.A.
  • Distributed in Canada by/Distribue au Canda par:Curium Canada Inc.Laval, QC, Canada, H7T-2R3DIN: 02441608
  • CURIUM n
  • A901C0R03/2019
  • Ultra-Technekow V4(TECHNETIUM Tc 99m GENERATOR)n n
  • WARNING
  • Rx only
  • See package insert for directions for use.
  • Tc-99m Half Life = 6 hr
  • CAUTIONn- RADIOACTIVE MATERIAL
  • Patent/Brevet/Patente:n n
  • Manufactured by/Fabrique par/Fabricado por:Curium USu00a0LLCMaryland Heights, MO 63043Made in USA/Fabrique aux Etats-Unis/Hecho en E.U.A.
  • Distributed in Canada by/Distribue au Canda par:Curium Canada Inc.Laval, QC, Canada, H7T-2R3DIN: 02441608
  • CURIUM n
  • A901C0R03/2019
  • Ultra-Technekow V4(TECHNETIUM Tc 99m GENERATOR)n n
  • WARNING
  • Rx only
  • See package insert for directions for use.
  • Tc-99m Half Life = 6 hr
  • CAUTIONn- RADIOACTIVE MATERIAL
  • Patent/Brevet/Patente:n n
  • Manufactured by/Fabrique par/Fabricado por:Curium USu00a0LLCMaryland Heights, MO 63043Made in USA/Fabrique aux Etats-Unis/Hecho en E.U.A.
  • Distributed in Canada by/Distribue au Canda par:Curium Canada Inc.Laval, QC, Canada, H7T-2R3DIN: 02441608
  • CURIUM n
  • A901C0R03/2019

Browse Our Services And Processes

Comparator Sourcing for Clinical Trials

Comparator Sourcing for Clinical Trials

GNH India brings over 10 years of experience in Comparator

Read More

Name Patient Supply

Name Patient Supply

Today, the exact cause for many rare diseases remains unknown

Read More

Validated Cold Chain Shipment

Validated Cold Chain Shipment

With shifting of pharma industry from synthetic molecules to biologic

Read More

Clinical Trials Supply

Clinical Trials Supply

STOP SOURCING..... START SMART SOURCING...... COME STRAIGHT TO THE SOURCE

Read More

Pharmaceutical Contract Manufacturing

Pharmaceutical Contract Manufacturing

GNH Provides Contract Manufacturing services for: Generic Medicines with following

Read More

Pricing

Pricing

PRICING POLICY Terms of sales are typically prepaid, unless otherwise

Read More

Disclaimer

Please see the Legal Notice for detailed terms and disclaimers. The Legal Notice governs the use of this Website and by accessing and using this Website you agree to be bound by and accept the Legal Notice.

Browse from other international pharmaceuticals

General

64020 Products

GNH India Brings to over 64036 Product SKUs from India all at 1 place with easy access and global deliveries.

US NDC

71245 Products

GNH India Brings to over 71252 Product SKUs from India all at 1 place with easy access and global deliveries.

Canadian DIN

51046 Products

GNH India Brings to over 51047 Product SKUs from India all at 1 place with easy access and global deliveries.

Swiss Drugs

150 Products

GNH India Brings to over 150 Product SKUs from India all at 1 place with easy access and global deliveries.

NZ Drugs

13296 Products

GNH Brings to over 13298 Product SKUs from India all at 1 place with easy access and global deliveries.

FAQ

Check out our delivery process

Can’t find what
you’re looking for?

Contact US
Pharmexcil
DB
FIEO-2016
SiteLock

Copyright © 2024 GNHIndia .com. All Rights Reserved. Please read Legal Notice for further details.

Disclaimer: Product names, logos, brands and other trademarks featured or referred to are the property of their respective trademark holders.